    World Precision Instruments noise gold ecg probe

    Noise Gold Ecg Probe, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/noise+gold+ecg+probe/ECG+Probe/bio_rxiv__2024__04__17__589909-281-17-11
    Average 94 stars, based on 1 article reviews
    noise gold ecg probe - by Bioz Stars, 2026-08
    94/100 stars

    Images

    1) Product Images from "Loss of developmentally derived Irf8+ macrophages promotes hyperinnervation and arrhythmia in the adult zebrafish heart"

    Article Title: Loss of developmentally derived Irf8+ macrophages promotes hyperinnervation and arrhythmia in the adult zebrafish heart

    Journal: bioRxiv

    doi: 10.1101/2024.04.17.589909


    Figure Legend Snippet:

    Techniques Used:

    (A) Cartoon depiction of the rack-compatible swim tunnel with metered flow. Following a 5-minute acclimation period within the tunnel, 12 mpf zebrafish were subjected to increasing flow rate intervals for a total of 1 hour. (B) Cartoon depiction of an ECG recording and a representative ECG trace from an anesthetized fish placed ventral-side up in a sponge surrounded by anesthesia solution. (C) Representative ECG traces for wild type and irf8 mutant zebrafish following the swim assay. Black arrows indicate unique electrical disturbances occurring above any baseline noise. (D) Percentage of fish with an abnormal electrical event during the ECG recording. Male n = 7 per genotype, ****p < 0.0001. Female n = 4-8 per genotype, ****p < 0.0001. Fisher’s exact test. (E) Categorization of ECG abnormalities observed throughout all wild type and irf8 mutant fish.
    Figure Legend Snippet: (A) Cartoon depiction of the rack-compatible swim tunnel with metered flow. Following a 5-minute acclimation period within the tunnel, 12 mpf zebrafish were subjected to increasing flow rate intervals for a total of 1 hour. (B) Cartoon depiction of an ECG recording and a representative ECG trace from an anesthetized fish placed ventral-side up in a sponge surrounded by anesthesia solution. (C) Representative ECG traces for wild type and irf8 mutant zebrafish following the swim assay. Black arrows indicate unique electrical disturbances occurring above any baseline noise. (D) Percentage of fish with an abnormal electrical event during the ECG recording. Male n = 7 per genotype, ****p < 0.0001. Female n = 4-8 per genotype, ****p < 0.0001. Fisher’s exact test. (E) Categorization of ECG abnormalities observed throughout all wild type and irf8 mutant fish.

    Techniques Used: Mutagenesis


    Figure Legend Snippet:

    Techniques Used:

    (A) Cartoon depiction of an adult zebrafish undergoing an echocardiogram with the transducer in the long-axis (LAX) position. Echocardiograms were performed on unchallenged fish. (B) Cartoon of an adult zebrafish heart from the perspective of the echocardiography recording, denoting the atrium (A), atrioventricular (AV) valve, ventriculobulbar (VB) valve, and bulbus arteriosus (BA). The boxes around the AV valve and VB valve depict the gating strategies to determine inward flow and outward flow of blood from the ventricle. (C) Still image from an adult zebrafish echocardiography recording with the ventricle and bulbus arteriosus outlined in red. (D) Representative echocardiogram trace gating on the AV valve with the early filling (E) wave, late filling (A) wave, diastasis time, isovolumic contraction time (IVCT), aortic ejection time (AET), and isovolumic relaxation time (IVRT) labeled. (E-G) Quantifications of IVRT (E), AET (F), and pressure within the VB valve (G) in male and female wild type and irf8 mutant fish at 6 and 12 mpf. Male n = 10-21 per genotype and timepoint. Female n = 9-14 per genotype and timepoint. Each point represents individual beats per fish. 8-10 beats were analyzed per fish. *p < 0.05; **p < 0.01; ***p < 0.001; ****p < 0.0001. (H) Quantification of heart in male and female wild type and irf8 mutants. (I) Representative echocardiogram traces from a wild type and irf8 mutant recording. (J-M) Quantification of diastasis time in wild type males (J) and females (K) at 6 mpf and 12 mpf, as well as diastasis time in irf8 mutant males (L) and females (M) at 6 mpf and 12 mpf. A Gaussian distribution was created by analyzing 8 beats per sample and grouping diastasis duration in defined increments. Male n = 10-21 per genotype and timepoint. Female n = 9-14 per genotype and timepoint. Horizontal bars represent the range of diastasis duration. (N-O) 95% confidence interval of the average diastasis time durations in wild type (gray) and irf8 mutant (blue) males (N) and females (O).
    Figure Legend Snippet: (A) Cartoon depiction of an adult zebrafish undergoing an echocardiogram with the transducer in the long-axis (LAX) position. Echocardiograms were performed on unchallenged fish. (B) Cartoon of an adult zebrafish heart from the perspective of the echocardiography recording, denoting the atrium (A), atrioventricular (AV) valve, ventriculobulbar (VB) valve, and bulbus arteriosus (BA). The boxes around the AV valve and VB valve depict the gating strategies to determine inward flow and outward flow of blood from the ventricle. (C) Still image from an adult zebrafish echocardiography recording with the ventricle and bulbus arteriosus outlined in red. (D) Representative echocardiogram trace gating on the AV valve with the early filling (E) wave, late filling (A) wave, diastasis time, isovolumic contraction time (IVCT), aortic ejection time (AET), and isovolumic relaxation time (IVRT) labeled. (E-G) Quantifications of IVRT (E), AET (F), and pressure within the VB valve (G) in male and female wild type and irf8 mutant fish at 6 and 12 mpf. Male n = 10-21 per genotype and timepoint. Female n = 9-14 per genotype and timepoint. Each point represents individual beats per fish. 8-10 beats were analyzed per fish. *p < 0.05; **p < 0.01; ***p < 0.001; ****p < 0.0001. (H) Quantification of heart in male and female wild type and irf8 mutants. (I) Representative echocardiogram traces from a wild type and irf8 mutant recording. (J-M) Quantification of diastasis time in wild type males (J) and females (K) at 6 mpf and 12 mpf, as well as diastasis time in irf8 mutant males (L) and females (M) at 6 mpf and 12 mpf. A Gaussian distribution was created by analyzing 8 beats per sample and grouping diastasis duration in defined increments. Male n = 10-21 per genotype and timepoint. Female n = 9-14 per genotype and timepoint. Horizontal bars represent the range of diastasis duration. (N-O) 95% confidence interval of the average diastasis time durations in wild type (gray) and irf8 mutant (blue) males (N) and females (O).

    Techniques Used: Labeling, Mutagenesis



    Similar Products

    94
    World Precision Instruments noise gold ecg probe

    Noise Gold Ecg Probe, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/noise+gold+ecg+probe/ECG+Probe/bio_rxiv__2024__04__17__589909-281-17-11
    Average 94 stars, based on 1 article reviews
    noise gold ecg probe - by Bioz Stars, 2026-08
    94/100 stars
      Buy from Supplier

    Image Search Results


    Journal: bioRxiv

    Article Title: Loss of developmentally derived Irf8+ macrophages promotes hyperinnervation and arrhythmia in the adult zebrafish heart

    doi: 10.1101/2024.04.17.589909

    Figure Lengend Snippet:

    Article Snippet: To record electrical impulses, we used the CardioPhys TM ECG system (World Precision Instruments), which included a low-noise gold ECG probe, micromanipulator, bio-amplifier and ground electrode, in combination with the PowerLab 2/26 data acquisition unit (ADInstruments, PL2602).

    Techniques:

    (A) Cartoon depiction of the rack-compatible swim tunnel with metered flow. Following a 5-minute acclimation period within the tunnel, 12 mpf zebrafish were subjected to increasing flow rate intervals for a total of 1 hour. (B) Cartoon depiction of an ECG recording and a representative ECG trace from an anesthetized fish placed ventral-side up in a sponge surrounded by anesthesia solution. (C) Representative ECG traces for wild type and irf8 mutant zebrafish following the swim assay. Black arrows indicate unique electrical disturbances occurring above any baseline noise. (D) Percentage of fish with an abnormal electrical event during the ECG recording. Male n = 7 per genotype, ****p < 0.0001. Female n = 4-8 per genotype, ****p < 0.0001. Fisher’s exact test. (E) Categorization of ECG abnormalities observed throughout all wild type and irf8 mutant fish.

    Journal: bioRxiv

    Article Title: Loss of developmentally derived Irf8+ macrophages promotes hyperinnervation and arrhythmia in the adult zebrafish heart

    doi: 10.1101/2024.04.17.589909

    Figure Lengend Snippet: (A) Cartoon depiction of the rack-compatible swim tunnel with metered flow. Following a 5-minute acclimation period within the tunnel, 12 mpf zebrafish were subjected to increasing flow rate intervals for a total of 1 hour. (B) Cartoon depiction of an ECG recording and a representative ECG trace from an anesthetized fish placed ventral-side up in a sponge surrounded by anesthesia solution. (C) Representative ECG traces for wild type and irf8 mutant zebrafish following the swim assay. Black arrows indicate unique electrical disturbances occurring above any baseline noise. (D) Percentage of fish with an abnormal electrical event during the ECG recording. Male n = 7 per genotype, ****p < 0.0001. Female n = 4-8 per genotype, ****p < 0.0001. Fisher’s exact test. (E) Categorization of ECG abnormalities observed throughout all wild type and irf8 mutant fish.

    Article Snippet: To record electrical impulses, we used the CardioPhys TM ECG system (World Precision Instruments), which included a low-noise gold ECG probe, micromanipulator, bio-amplifier and ground electrode, in combination with the PowerLab 2/26 data acquisition unit (ADInstruments, PL2602).

    Techniques: Mutagenesis

    (A) Cartoon depiction of an adult zebrafish undergoing an echocardiogram with the transducer in the long-axis (LAX) position. Echocardiograms were performed on unchallenged fish. (B) Cartoon of an adult zebrafish heart from the perspective of the echocardiography recording, denoting the atrium (A), atrioventricular (AV) valve, ventriculobulbar (VB) valve, and bulbus arteriosus (BA). The boxes around the AV valve and VB valve depict the gating strategies to determine inward flow and outward flow of blood from the ventricle. (C) Still image from an adult zebrafish echocardiography recording with the ventricle and bulbus arteriosus outlined in red. (D) Representative echocardiogram trace gating on the AV valve with the early filling (E) wave, late filling (A) wave, diastasis time, isovolumic contraction time (IVCT), aortic ejection time (AET), and isovolumic relaxation time (IVRT) labeled. (E-G) Quantifications of IVRT (E), AET (F), and pressure within the VB valve (G) in male and female wild type and irf8 mutant fish at 6 and 12 mpf. Male n = 10-21 per genotype and timepoint. Female n = 9-14 per genotype and timepoint. Each point represents individual beats per fish. 8-10 beats were analyzed per fish. *p < 0.05; **p < 0.01; ***p < 0.001; ****p < 0.0001. (H) Quantification of heart in male and female wild type and irf8 mutants. (I) Representative echocardiogram traces from a wild type and irf8 mutant recording. (J-M) Quantification of diastasis time in wild type males (J) and females (K) at 6 mpf and 12 mpf, as well as diastasis time in irf8 mutant males (L) and females (M) at 6 mpf and 12 mpf. A Gaussian distribution was created by analyzing 8 beats per sample and grouping diastasis duration in defined increments. Male n = 10-21 per genotype and timepoint. Female n = 9-14 per genotype and timepoint. Horizontal bars represent the range of diastasis duration. (N-O) 95% confidence interval of the average diastasis time durations in wild type (gray) and irf8 mutant (blue) males (N) and females (O).

    Journal: bioRxiv

    Article Title: Loss of developmentally derived Irf8+ macrophages promotes hyperinnervation and arrhythmia in the adult zebrafish heart

    doi: 10.1101/2024.04.17.589909

    Figure Lengend Snippet: (A) Cartoon depiction of an adult zebrafish undergoing an echocardiogram with the transducer in the long-axis (LAX) position. Echocardiograms were performed on unchallenged fish. (B) Cartoon of an adult zebrafish heart from the perspective of the echocardiography recording, denoting the atrium (A), atrioventricular (AV) valve, ventriculobulbar (VB) valve, and bulbus arteriosus (BA). The boxes around the AV valve and VB valve depict the gating strategies to determine inward flow and outward flow of blood from the ventricle. (C) Still image from an adult zebrafish echocardiography recording with the ventricle and bulbus arteriosus outlined in red. (D) Representative echocardiogram trace gating on the AV valve with the early filling (E) wave, late filling (A) wave, diastasis time, isovolumic contraction time (IVCT), aortic ejection time (AET), and isovolumic relaxation time (IVRT) labeled. (E-G) Quantifications of IVRT (E), AET (F), and pressure within the VB valve (G) in male and female wild type and irf8 mutant fish at 6 and 12 mpf. Male n = 10-21 per genotype and timepoint. Female n = 9-14 per genotype and timepoint. Each point represents individual beats per fish. 8-10 beats were analyzed per fish. *p < 0.05; **p < 0.01; ***p < 0.001; ****p < 0.0001. (H) Quantification of heart in male and female wild type and irf8 mutants. (I) Representative echocardiogram traces from a wild type and irf8 mutant recording. (J-M) Quantification of diastasis time in wild type males (J) and females (K) at 6 mpf and 12 mpf, as well as diastasis time in irf8 mutant males (L) and females (M) at 6 mpf and 12 mpf. A Gaussian distribution was created by analyzing 8 beats per sample and grouping diastasis duration in defined increments. Male n = 10-21 per genotype and timepoint. Female n = 9-14 per genotype and timepoint. Horizontal bars represent the range of diastasis duration. (N-O) 95% confidence interval of the average diastasis time durations in wild type (gray) and irf8 mutant (blue) males (N) and females (O).

    Article Snippet: To record electrical impulses, we used the CardioPhys TM ECG system (World Precision Instruments), which included a low-noise gold ECG probe, micromanipulator, bio-amplifier and ground electrode, in combination with the PowerLab 2/26 data acquisition unit (ADInstruments, PL2602).

    Techniques: Labeling, Mutagenesis